Select Page

MF Series

Laboratory muffle furnace up to 1400°C, 4 heated sides and vertical opening for continuous operation with modern lines

Laboratory muffle furnace with a modern, robust, compact, bench-top, high quality design with maximum temperatures of 1000ºC – 1200ºC – 1300ºC – 1400ºC with 4 heated sides offering high homogeneity, stability and fast heating, vertical opening.

Standard Equipment

  • Volumes from 3 to 40 liters
  • Maximum temperatures of 1000ºC, 1200ºC, 1300ºC, 1400ºC
  • Ramp programmer up to 64 steps
  • 4 heated sides
  • Vertical lift opening 
  • Ceramic tray
  • Inox chamber 
  • Double casing with air chamber to have low surface temperature
  • Solid state relays provide for low noise operation
  • Safety switch
  • Safety contactor 
  • Heating pilot light
  • Thermocouples K (1000ºC-1200ºC) or S (1300-1400ºC)
  • Homogeneity +/-5ºC – Stability +/-1ºC
  • Furnace shutdown in case of thermocouple breakage
  • Furnace switch-off when door is opened
  • Chimney at the rear of the furnace
  • Ventilation at the rear of the furnace focused on the electrical elements
  • Furnace control at the bottom of the furnace

PR Series

Laboratory and Industrial muffle furnace up to 1400°C, 4 heated sides and Pantograph side opening for continuous operation with sturdy lines

Laboratory and industrial muffle furnace sturdy, compact, bench-top, high quality design with maximum temperatures of 1000ºC – 1200ºC – 1300ºC – 1400ºC with 4 heated sides offering high homogeneity, stability and fast heating, pantograph side door.

Standard Equipment

  • Volumes from 3 to 40 liters
  • Maximum temperatures of 1000ºC, 1200ºC, 1300ºC, 1400ºC
  • Ramp programmer up to 64 steps
  • 4 heated sides
  • Vertical lift opening
  • Ceramic tray
  • Double casing with air chamber to have low surface temperature
  • Solid state relays provide for low noise operation
  • Safety switch
  • Safety contactor
  • Heating pilot light
  • Thermocouples K (1000ºC-1200ºC) or S (1300-1400ºC)
  • Homogeneity +/-5ºC – Stability +/-1ºC
  • Furnace shutdown in case of thermocouple breakage
  • Chimney at the rear of the furnace
  • Furnace control at the bottom of the furnace

GB Series

Economical muffle furnace up to 1,200ºC

Economy laboratory muffle furnace in a modern, compact, table-top design with a convincing price/performance ratio and maximum temperatures of 1200°C with 2 heated sides and side opening.

Standard Equipment

  • Volumes: 3, 7, 10 and 15 litres
  • maximum temperature 1200ºC
  • Ramp programmer up to 64 steps
  • 2 heated sides
  • Side opening
  • Ceramic tray
  • Double casing with air chamber to have low surface temperature
  • Solid state relays provide for low noise operation
  • Thermocouples K (1200ºC)
  • Homogeneity +/-5ºC – Stability +/-1ºC
  • Furnace shutdown in case of thermocouple breakage
  • Chimney at the rear of the furnace
  • Ventilation at the rear of the furnace focused on the electrical elements
  • Furnace control at the bottom of the furnace

HD Series (Economic Series)

Economical muffle furnace up to 1,200ºC

Economy laboratory muffle sturdy and table-top design with a convincing price/performance ratio and maximum temperatures of 1200°C with 3 heated sides and side and drop down opening.

Standard Equipment

  • Volumes: from 1,6 to 40 liters maximum temperature 1200ºC
  • Ramp programmer up to 64 steps
  • 3 heated sides
  • Side or drop down opening
  • Ceramic tray
  • Solid state relays provide for low noise operation
  • Thermocouples K (1200ºC)
  • Homogeneity +/-5ºC – Stability +/-1ºC
  • Furnace shutdown in case of thermocouple breakage
  • Chimney at the rear of the furnace
  • Ventilation at the rear of the furnace focused on the electrical elements
  • Furnace control at the bottom of the furnace

JM Series

High temperature muffle furnaces up to 1600ºC, fast heating, vertical lift door heated by SiC Kanthal

JM laboratory muffle furnaces are available for temperatures up to 1600 °C. The durability of the SiC Kanthal rods in regular use, combined with their high heating speed, make these high-temperature furnaces all-rounders in the laboratory. Very fast heat-up times and vertical door opening to protect the user from heat radiation.

Standard Equipment

  • Volumes from 3 to 38 liters
  • Maximum temperature up to 1600ºC
  • Ramp programmer up to 64 steps
  • Heated by SiC Kanthal
  • Vertical lift opening
  • Inox chamber
  • Double casing with air chamber to have low surface temperature
  • Solid state relays provide for low noise operation
  • Safety switch
  • Safety contactor
  • Heating pilot light
  • Thermocouple S (1600ºC)
  • Homogeneity +/-5ºC – Stability +/-1ºC
  • Furnace shutdown in case of thermocouple breakage
  • Furnace switch-off when door is opened
  • Chimney at the rear of the furnace
  • Ventilation at the rear of the furnace focused on the electrical elements
  • Furnace control at the bottom of the furnace

    XG Series

    High temperature muffle furnaces up to 1900ºC, fast heating, vertical lift door heated by Kanthal Super 1800 and 1900

    High temperature muffle furnace heated with MoSi2 Kanthal Super 1800 and 1900 MoSi2 heating elements. High density ceramic fibre insulation manufactured in Europe that offers great homogeneity and energy savings. Vertical door opening to protect the user from thermal radiation. Compact, modern design, robust and of high quality allowing continuous high temperature work.

    High-quality 100 mm insulation and air chamber allow continuous operation without overheating of the outer surface.

    Standard Equipment

    • Volumes from 3 to 30 liters
    • Maximum temperature up to 1650ºC – 1800ºC and 1900ºC
    • Ramp programmer up to 64 steps
    • Heated by MoSi2 Kanthal Super 1800 and 1900
    • Vertical lift opening
    • Inox chamber
    • Double casing with air chamber to have low surface temperature
    • Solid state relays provide for low noise operation
    • Safety switch
    • Safety contactor
    • Heating pilot light
    • Thermocouple S and B (1600ºC to 1900ºC)
    • Homogeneity +/-5ºC – Stability +/-1ºC
    • Furnace shutdown in case of thermocouple breakage
    • Furnace switch-off when door is opened
    • Chimney at the rear of the furnace
    • Ventilation at the rear of the furnace focused on the electrical elements
    • Furnace control at the bottom of the furnace