 | digiDART™ Portable HPGe MCA. The new ORTEC DigiDART is an extraordinary, portable, HPGe-grade Multichannel Analyzer. It has been carefully engineered to perform the most demanding real world, PORTABLE gamma-ray spectroscopy applications. - High-performance RUGGED HPGe grade spectrometer, 16k channels
- DIGITALLY stable: consistent answers for long counts, changing count-rates and temperatures
- Operates WITHOUT an attached PC
- Built-in backlit LCD display and control keypad — Live display of acquiring data
- Energy calibration using keypad
- Nuclide ID and activity calculation for nine Regions of Interest (ROI)
- High throughput — over 100,000 processed pulses per second
- Battery life >9 hours
- Fast USB communications
| | |  | MicroNOMAD™ Portable, Miniature MCA for Use with NaI(Tl), CZT, and Other Moderate-Resolution. MicroNOMAD is a truly remarkable, micromultichannel analyzer. Small, low-power, light MicroNOMAD has been specifically designed for gamma spectroscopy with moderate-resolution detectors, such as NaI(Tl) and CZT — wherever small size, portability, and battery life are of paramount concern. Controlled via PC, as is any modern MCA, MicroNOMAD has a unique “field mode” that allows acquisition of up to 63 spectra, with no PC connected!! The MicroNOMAD package comes complete with parallel connection cable and MCA/Quantitative analysis software. In conjunction with any PC (portable or desktop), MicroNOMAD is ready to spring into action for your application. | | |  | ISO-CART™ Mobile Assay System. A Complete In-Situ NDA Gamma-Ray Analysis for a Wide Variety of Samples. The ISO-CART Mobile NDA System is an ideal solution for a wide variety of in-situ gamma-ray measurement requirements. The hardware comprises a specially-designed cart which carries all the components: HPGe detector, shield and collimator, digiDART™ high performance multichannel analyzer, and laptop computer. - Measures all common geometries: pipes, cylinders, floors, ceilings, walls, drums, boxes, and soils
- Easy-roll cart for maneuvering over any surface
- Wide selection of collimators and shields available for different measurement situations
- Continuous height adjustment and variable tilt adjustment
- ISOTOPIC software, proven results on thousands of realworld samples
- Flexible reporting: measurement results can be reported in grams or activity (Bq or Ci)
| | |  | HPGe Interchangeable Detector Module (IDM) Intelligent, Modular Solutions to Portal Monitoring System Needs for Illicit Nuclear and Radiological Material Interdiction. The ORTEC Interchangeable Detector Module or IDM is a gamma-ray detection “building block.” The IDM is a completely self-contained subsystem, comprising a single, mechanically cooled high-purity germanium (HPGe) detector of standardized crystal dimensions and all necessary electronics in a RUGGED package. It is everything needed to detect gamma rays and send the energy histogram or digitized pulse stream to a PC for analysis. - Large area 85 mm x 30 mm HPGe crystal
- High-reliability Stirling cycle cooler cools rapidly to operating temperature
- Hardened cryostat designed for long operational life
- Can be temperature cycled at any time, even from partial warm up
- High performance, digitally stable signal processing
- “Hot swap” of IDM modules while in operational state – reduced downtime
- USB 2.0 data communications
- Continuous data collection, no dead spots, using list mode
- Low power consumption
- Low Frequency Rejector (LFR) improves spectrum resolution in noisy environments
| | |  | High Resolution Systems for Aerial Survey Detective-AERO High Resolution HPGe Aerial Radiation Monitoring Systems Intelligent, Modular Solutions to Your Aerial Monitoring System Needs for Nuclear and Radiological Material Detection and Mapping. - Real-time Gamma-Ray Monitoring from the air
- Find Lost Sources, Unauthorized Sources, or Contamination Boundaries
- Alarms when your selected sources are found
- Simultaneous identification and detection in real time
- Meets National and International Standards for Mobile Search Systems
- Nuclide Specific Position Mapping of activity using GPS provided location
- Continuous data collection - no dead spots
- Highly visible activity display
- Spectrum, time and GPS stored in data base for easy post scan analysis
- Electrical cooling, no liquid nitrogen
- Noise and vibration tolerant
- Compact package - easy to install and service
| | |  | NaI-SS Radiation Search Systems Medium Resolution Systems for Mobile Search High Sensitivity to Gamma and Neutron Radiation, Conveniently Packaged in a Rugged Plastic "Pelican Type" Container. - Real time Gamma and Neutron Monitoring of the environment from the ground or air
- Locates Illicit Transport of sources or lost sources
- Alarms when sources found
- Detects Radiological Dispersion Device (RDD) material and Special Nuclear Material (SNM)
- Position Mapping of activity
- No Loss of data between time slices
- GPS provides accurate location mapping of vehicle and source distribution
- High visible activity display
- Powerful post-detection analysis
- Omni directional sensitivity
| | |  | trans-SPEC and trans-SPEC-100 Battery Powered Portable HPGe Gamma Spectrometer. The really practical solution for mobile germanium high-resolution HPGe Gamma Spectrometer for in-situ gamma spectroscopy, improved: Miniature high-reliability, "run for ever" Stirling-cycle cooler eliminates the need for LIQUID NITROGEN; Detector element encapsulated in high reliability, low loss, all-metal sealed cryostat. New 100 model means you can meet your required MDA in even lower counting times with the large (>40% relative efficiency) HPGe detector. All-in-one rugged, compact integrated package Nuclide ID and activity calculation for nine Regions of Interest (ROI). Holds >90 4k spectra in internal memory. Fast USB communications, hooks straight to your laptop (MAESTRO-32 software included). Use any power source: internal battery, supplemental external battery, automobile battery (any 12 V dc), line power; all with automatic switchover.
| | |  | Portable Isotopic Neutron Spectroscopy Chemical Weapons Assay System.
Second Generation Neutron Based NDE System for Identification of Chemical Warfare Agents, Explosives, and Toxic Industrial Chemicals. - Identifies Chemical Contents of Munitions and other containers safely and reliably by Nondestructive and non-contact method: no direct sampling or need to breach container or over pack required.
- Highly penetrating Neutron Radiation passes through even the thickest metal containers to expose the contents
- Chemical fingerprinting algorithms developed over thousands of real world examples
- Portable Spectrometer brings digital signal processing and "SMART" detector technology
- Compact and simple to assemble
- Suitable for both Military and Civil Defense use
- Assay Times: 100 to 1000 seconds
| | |
|